Skip to the main content

Preliminary communication

https://doi.org/10.14256/JCE.2755.2019

Effect of openings on cold formed steel shear wall panels

Idriss Rouaz
Nouredine Bourahla
Smail Kechidi


Full text: croatian pdf 427 Kb

page 771-780

downloads: 207

cite

Full text: english pdf 413 Kb

page 771-780

downloads: 339

cite


Abstract

In this paper, the effect of openings on global performance of Cold Formed Steel Shear Wall Panels is investigated numerically using the ABAQUS software. A benchmark model is first validated in terms of lateral shear capacity and nonlinear behaviour of the CFS-SWP. The failure mode of the CFS-SWP with opening is identified and validated. Subsequently, a parametric study on the effect of size and position of openings is conducted, in which the opening position is found to have a significant impact on the CFS-SWP performance. The benchmark model can be used for design purposes to evaluate with good accuracy the reduced ultimate strength of individual CFS-SWPs for any size and position of openings.

Keywords

cold formed steel shear wall panel; shear strength; nonlinear behaviour; connection failure; opening effect

Hrčak ID:

246875

URI

https://hrcak.srce.hr/246875

Publication date:

19.10.2020.

Article data in other languages: croatian

Visits: 1.123 *