Tehnički glasnik, Vol. 14 No. 4, 2020.
Pregledni rad
https://doi.org/10.31803/tg-20180206150332
THD Analysis of a Seven, Nine, and Eleven Level Cascaded H-Bridge Multilevel Inverter for Different Loads
Manoj Kumar Sahu
orcid.org/0000-0002-7239-2539
; Department of Electrical Engineering, Centre for Advanced Post Graduate Studies, BPUT, Chhend Campus, Rourkela, Odisha-769015, India
Madhusmita Biswal
; Government ITI Berhampur, Berhampur, Odisha-769015, India
Jagan Mohana Rao Malla
; Department of Electronics and Communication Engineering, Rishi Institute of Engineering and Technology for Woman, Kukatpally, Hyderabad-500090, India
Sažetak
A multilevel inverter is implemented for generating the required staircase AC voltage of output from various steps of voltages of DC sources. The multilevel inverter gives a better harmonic spectrum and a compatible quality of output. This article delves into an analytical analysis of the total harmonic distortion (THD) of different multilevel inverters which employ a multicarrier PWM technique. This technique is implemented for operating the switches at their respective angle of conduction. This paper deals with various cascaded H-Bridge multilevel inverters (CMI) with various loads that are modelled by implementing the MATLAB/Simulink platform. The output gives a better result of the proposed model in terms that it is helpful towards reducing the THD and the losses of switching.
Ključne riječi
APOD; CMI; IPD; phase shifted modulation technique; POD; THD
Hrčak ID:
247430
URI
Datum izdavanja:
9.12.2020.
Posjeta: 1.856 *