Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.15644/asc54/4/2

Assessment of Color Parameters on Maxillary Right Central Incisors Using Spectrophotometer and RAW Mobile Photos in Different Light Conditions

Mirko Soldo ; Stomatološka ordinacija Doma zdravlja Osječko-baranjske županije, Osijek, Hrvatska
Davor Illeš ; Zavod za mobilnu protetiku Stomatološkog fakulteta Sveučilišta u Zagrebu, Zagreb, Hrvatska
Robert Ćelić ; Zavod za mobilnu protetiku Stomatološkog fakulteta Sveučilišta u Zagrebu, Zagreb, Hrvatska
Dubravka Knezović Zlatarić ; Zavod za mobilnu protetiku Stomatološkog fakulteta Sveučilišta u Zagrebu, Zagreb, Hrvatska


Puni tekst: engleski pdf 255 Kb

str. 353-362

preuzimanja: 636

citiraj

Puni tekst: hrvatski pdf 255 Kb

str. 353-362

preuzimanja: 242

citiraj


Sažetak

Objectives: The aim of the study was to compare three color parameters assessed on the maxillary right central incisors using a spectrophotometer as the gold standard, along with RAW mobile calibrated and non-calibrated photos in different light conditions. Materials and methods: A total of 30 dental students participated in the study. CIE L*a*b* values were measured in the middle third of each maxillary right central incisor spectrophotometrically and digitally on RAW mobile dental photos using different light conditions (F-frontal light; L-lateral light; D-lateral light with diffusers; P- polarizing filter on frontal light; H-hybrid filter as combination of frontal light with polarizing filter and lateral lights with diffusers) with LEDs (light emitting diode) in full power, and with gray card calibration. The obtained results were compared. Results: Mean a* and b* values on calibrated, as well as mean L* values on non-calibrated RAW mobile photos did not significantly differ in different light conditions (P>0.05). CIE L*a*b* values on non-calibrated polarizing RAW mobile photos completely matched the same values obtained using a spectrophotometer on the subject’s maxillary right central incisor (P>0.05). Conclusions: Different light conditions and measuring procedures affected CIE L*a*b* values on RAW mobile photos in this study. Within the limitations, non-calibrated RAW mobile photos using a lightening device with polarizing filters on frontal LED light in standardized conditions can be a useful tool for digital dental shade determination.

Ključne riječi

Dental Esthetics; Tooth Color; Color Shade; Dental Photography; Cell Phone Use

Hrčak ID:

247645

URI

https://hrcak.srce.hr/247645

Datum izdavanja:

14.12.2020.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.841 *