Lead Toxicity in a Family as a Result of Occupational Exposure

Aryapu Raviraja orcid id orcid.org/0000-0001-8833-1995 ; Department of Biochemistry and Biophysics, St. John’s Medical College, Koramangala
Gaja Narayanamurthy Vishal Babu ; Department of Biochemistry and Biophysics, St. John’s Medical College, Koramangala
Anita Raghuveer Bijoor ; Department of Biochemistry and Biophysics, St. John’s Medical College, Koramangala
Geraldine Menezes ; Department of Biochemistry and Biophysics, St. John’s Medical College, Koramangala
Thuppil Venkatesh


Full text: english pdf 73 Kb

page 127-133

downloads: 1.352

cite


Abstract

This article describes an entire family manufacturing lead acid batteries who all suffered from lead poisoning. The family of five lived in a house, part of which had been used for various stages of battery production for 14 years. Open space was used for drying batteries. They all drank water from a well located on the premises. Evaluation of biomarkers of lead exposure and/or effect revealed alarming blood lead levels [(3.92±0.94) µmol L-1], 50 % reduction in the activity of δ-aminolevulinic acid dehydratase [(24.67±5.12) U L-1] and an increase in zinc protoporphyrin [(1228±480) µg L-1]. Liver function tests showed an increase in serum alkaline phosphatase [(170.41±41.82) U L-1]. All other liver function test parameters were normal. Renal function tests showed an increase in serum uric acid [(515.81±86.29) µmol L-1] while urea and creatinine were normal. Serum calcium was low [(1.90±0.42) mmol L-1 in women and (2.09±0.12) mmol L-1 in men], while blood pressure was high in the head of the family and his wife and normal in children. Lead concentration in well water was estimated to 180 µg L-1. The family was referred to the National Referral Centre for Lead Poisoning in India, were they were received treatment and were informed about the hazards of lead poisoning. A follow up three months later showed a slight decrease in blood lead levels and a significant increase in haemoglobin. These findings can be attributed to behavioural changes adopted by the family, even though they continued producing lead batteries.

Keywords

blood lead; chelation therapy; lead acid battery; lead poisoning

Hrčak ID:

24821

URI

https://hrcak.srce.hr/24821

Publication date:

23.6.2008.

Article data in other languages: croatian

Visits: 3.017 *