Izvorni znanstveni članak
Sensitive determination of uric acid at layered zinc hydroxide-sodium dodecyl sulphate-propoxur nanocomposite
Mohamad Hafiz Ahmad Tajudin
; Department of Chemistry, Faculty of Science and Mathematics, Universiti Pendidikan Sultan Idris, 35900 Tanjong Malim, Perak, Malaysia
Mohamad Syahrizal Ahmad
orcid.org/0000-0002-9278-6332
; Department of Chemistry, Faculty of Science and Mathematics, Universiti Pendidikan Sultan Idris, 35900 Tanjong Malim, Perak, Malaysia
Illyas Md Isa
; Department of Chemistry, Faculty of Science and Mathematics, Universiti Pendidikan Sultan Idris, 35900 Tanjong Malim, Perak, Malaysia
Norhayati Hashim
; Department of Chemistry, Faculty of Science and Mathematics, Universiti Pendidikan Sultan Idris, 35900 Tanjong Malim, Perak, Malaysia
Anwar Ul-Hamid
; Center for Engineering Research, Research Institute, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia
Mohamad Idris Saidin
; Department of Chemistry, Faculty of Science and Mathematics, Universiti Pendidikan Sultan Idris, 35900 Tanjong Malim, Perak, Malaysia
Rahadian Zainul
; Department of Chemistry, Faculty of Mathematics and Natural Science, Universitas Negeri Padang, West Sumatera 25171, Indonesia
Suyanta M. Si
; Department of Chemistry Education, Faculty of Mathematics and Natural Science, Yogyakarta State University, Indonesia
Sažetak
An electrochemical chemical sensor for the determination of uric acid (UA) with high sensitivity and a wide working range was fabricated using the layered zinc hydroxide-sodium dodecyl sulphate-propoxur (LZH-SDS-PRO) nanocomposite, modified with multiwall carbon nanotubes (MWCNT). The introduction of LZH-SDS-PRO as a conducting matrix has enhanced the conductivity of MWCNT. The morphology of LZH-SDS-PRO/MWCNT was characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM), while electrochemical behavior of UA and K3[Fe(CN)6] at LZH-SDS-PRO/MWCNT paste electrode was studied by square wave and cyclic voltammetry, respecttively. Under the optimized experimental conditions, the electrode established linear plot for UA concentrations 7.0 mol L-1 to 0.7 mmol L-1 (R2 = 0.9920) and LOD was calculated to be 4.28 µmol L-1 (S/N = 3). The fabricated LZH-SDS-PRO/MWCNT electrode was successsfully applied to urine samples, exhibiting excellent stability and reproducibility, which made it worthwhile for analytical applications.
Ključne riječi
Hrčak ID:
273960
URI
Datum izdavanja:
7.3.2022.
Posjeta: 880 *