Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.14256/JCE.3418.2021

Seismic response of post-tension shear walls – Outrigger structure

Mohamed Husain
Hilal Hassan
Heba A. Mohamed
Eman Saeed Elgharbawy


Puni tekst: hrvatski pdf 3.226 Kb

str. 491-502

preuzimanja: 146

citiraj

Puni tekst: engleski pdf 3.207 Kb

str. 491-502

preuzimanja: 130

citiraj


Sažetak

This research was conducted by combining two structural systems: post-tensioned core walls and an outrigger in a 40-story building. A Vierendeel outrigger system was applied to one and two stories, and a comparison between models was performed to determine the best outrigger locations. In addition, the effect of post-tensioned core walls at only 25 % of the building height was investigated. Subsequently, the best positions of the Vierendeel outrigger system were applied with bonded post-tension core walls at a building height of only 25 %. The results showed an improvement in lateral stiffness using the outrigger, and roof displacement was enhanced by approximately 42 %. The post-tension core walls enhanced roof displacement by approximately 14 %. Both systems worked together to reduce roof displacement by approximately 50 %.

Ključne riječi

Outrigger system; post-tension shear walls; time history earthquake; seismic response; Midas-Gen software program

Hrčak ID:

281128

URI

https://hrcak.srce.hr/281128

Datum izdavanja:

24.7.2022.

Podaci na drugim jezicima: hrvatski

Posjeta: 680 *