Skoči na glavni sadržaj

Stručni rad

DETECTION OF HEARING IMPAIRMENT IN HOSPITAL MATERNITY WARD VIROVITICA

Nives Kolar ; Opća bolnica Virovitica
Ksenija Mikulčić ; Opća bolnica Virovitica
Milica Ivanic ; Opća bolnica Virovitica


Puni tekst: hrvatski PDF 241 Kb

str. 33-36

preuzimanja: 32

citiraj

Puni tekst: engleski pdf 241 Kb

str. 33-36

preuzimanja: 37

citiraj


Sažetak

Abstract
The aim of this study was to investigate the prevalence of hearing impairment in
newborns using automatic otoacoustic emission (A-OAE) in Virovitica County Hospital
Maternity Ward. Screening includes all newborns born in the period from 2012-2014.
Hearing was tested on 2188 (98.9%) newborns among which 133 (6.1%) had positive
hearing impairment results. 9 (0.4%) newborns had positive results and were reffered to
a secondary institution (Policlinic SUVAG, Zagreb) where 3 (0,14%) of them were
confirmed hearing impairment. Results confirm the importance of early screening for
hearing impairment of all newborns after birth in maternity ward.

Ključne riječi

hearing impairment, newborns, otoacoustic emission

Hrčak ID:

298416

URI

https://hrcak.srce.hr/298416

Datum izdavanja:

7.10.2015.

Podaci na drugim jezicima: hrvatski

Posjeta: 158 *