Technical gazette, Vol. 19 No. 3, 2012.
Original scientific paper
Assessing RGB device calibration control level
Davor Donevski
orcid.org/0000-0003-3837-0456
; Faculty of Graphic Arts, University of Zagreb, Getaldićeva 2, 10000 Zagreb, Croatia
Diana Milčić
; Faculty of Graphic Arts, University of Zagreb, Getaldićeva 2, 10000 Zagreb, Croatia
Iva Šarčević
; Faculty of Graphic Arts, University of Zagreb, Getaldićeva 2, 10000 Zagreb, Croatia
Abstract
Colour reproduction devices are calibrated with the aim of maximizing their performance and setting them in a known state. Many calibration methods have been developed for colour reproduction devices which provide direct control over their colorants’ amounts (CMYK devices). Devices with no direct control over their colorants’ amounts are normally not calibrated and are therefore less accurate regarding the colour reproduction. This paper investigates the possibilities of calibrating such devices, i.e. the level of control that can be established over them. For that purpose, basic principles of the existing calibration methods were taken, but the method of determining the aimed values was modified and extended with novelties. The evaluation showed that this attempt did result in some improvements, however, should be studied more carefully as it was revealed that the process was uncontrolled in some aspects.
Keywords
calibration; characterization; colour reproduction device
Hrčak ID:
86736
URI
Publication date:
19.9.2012.
Visits: 1.682 *