Skip to the main content

Original scientific paper

Range Definition of Acceptable Differences of Chromatic Value by Color Measurement and Visual Estimation

Nina Knešaurek ; Faculty of Graphic Arts, HR 10000 Zagreb, Getaldićeva 2


Full text: english pdf 16.751 Kb

page 955-969

downloads: 410

cite


Abstract

Under the defined conditions, 24 samples, considered to be similar to the chosen standards in their chromatic characteristics, were chosen by the visual method among 126 similar samples. The standard and all the tested (investigated) samples were measured on the spectral photometer. The measured reflenctandes were recalculated into numerical values of CIELAB. Based on the data obtained by the instrumental method, the developed differences of 24 visually similar samples were calculated and analyzed. The limits of the visual judgment expressed as AL*, AH*a^, AC*aj, were numerically defined. The developed color differences are usually defined by one numerical data, i.e., ABased on the analysis of the calculated chromatic values of CIELAB and their chromatic influence in the visual estimation of the change of the expression of AE*ab, it is suggested to use three numerical values, AL*, &H*ab, AC*ab, to define color differences. In this way, the values that caused the developed differences can be defined.

Keywords

Hrčak ID:

135665

URI

https://hrcak.srce.hr/135665

Publication date:

3.11.1997.

Visits: 978 *