Skip to the main content

Preliminary communication

https://doi.org/10.14256/JCE.1112.2014

Experimental studies on corrugated steel-concrete composite slab

Hajir Satih Abbas
Sohaimi Abu Bakar
Mohammad Ahmadi
Zaiton Haron


Full text: croatian pdf 707 Kb

page 225-233

downloads: 2.474

cite

Full text: english pdf 696 Kb

page 225-233

downloads: 1.604

cite


Abstract

Composite deck slabs are composed of normal concrete and corrugated steel sheet. The strength of composite slabs is governed by shear interaction between the concrete and the steel deck. This interaction depends on several factors and no relationship criteria can be found for interaction property from analytical basis. Therefore, the analysis and design methods are used by means of empirical analysis. In this paper, the experimental work is conducted to develop a new scale test method by using two lines of shear connectors welded onto the corrugated plate and lateral beam, in order to increase the shear bond resistance of a composite slab.

Keywords

composite slab; shear connector; corrugated steel plate; longitudinal failure and experimental test

Hrčak ID:

137752

URI

https://hrcak.srce.hr/137752

Publication date:

14.4.2015.

Article data in other languages: croatian

Visits: 5.249 *