Skip to the main content

Original scientific paper

https://doi.org/10.17559/TV-20150519103549

Storage tank for a single-person household providing same flow conditions as for calibration measurements by water meter

Lajos Hovány orcid id orcid.org/0000-0002-3378-0600 ; University of Novi Sad, Faculty of Civil Engineering Subotica, Kozaračka 2a, 24000 Subotica, Serbia


Full text: croatian pdf 1.041 Kb

versions

page 1701-1706

downloads: 508

cite

Full text: english pdf 1.041 Kb

versions

page 1701-1706

downloads: 285

cite


Abstract

In order to ensure the same conditions as for flow calibration, in case of a single-person household provided with a class B multi-jet propeller water meter with nominal diameter of 20 mm, a thermally insulated storage tank was built. During the exploitation, the storage tank will be fed by calibrated constant discharges in stages. For the purposes of measured consumption cumulative curve, the needed tank volume, flow rate and minimum duration of the filling stage were defined in the function of water meter reading accuracy (1 litre, 0,1 litre and 0,025 litre). The measurements proved that the thermally insulated tanks were able to keep water temperature within the range identical to that measured in the water supply in a single-person household.

Keywords

single-person household; storage tank; water meter calibration; water meter reading accuracy; water temperature

Hrčak ID:

169358

URI

https://hrcak.srce.hr/169358

Publication date:

29.11.2016.

Article data in other languages: croatian

Visits: 1.669 *