Technical gazette, Vol. 24 No. 1, 2017.
Preliminary communication
https://doi.org/10.17559/TV-20150502231618
Simulation of the impact of higher harmonics on the transient process of induction machine fed from PWM inverters
Nenad Marković
orcid.org/0000-0001-6960-1953
; Advanced Polytechnic School of Vocational Studies Uroševac, 24. Novembar, 38218 Leposavić, Srbija
Slobodan Bjelić
; Faculty of Technical Sciences Kosovska Mitrovica, University of Priština, Kneza Miloša 7, 38220 Kosovska Mitrovica, Srbija
Jeroslav Živanić
; Faculty of Technical Sciences Čačak, University of Kragujevac, Svetog Save 65, 32000 Čačak, Srbija
Uroš Jakšić
; Advanced Polytechnic School of Vocational Studies Zvečan Nušićeva 6, 38227 Zvečan, Srbija
Abstract
In this paper a fundamental mathematical model (algorithm) for determination of condition of induction machine as well as the simulation procedure for measurement of certain values in program MATLAB has been presented. A scheme of measuring system and results of simulation application are presented on output lists. Thus, measuring system gradually develops and improves as combination of information and results of previous steps in modeling with new elements essential for development of researches when induction machine is fed through PWM inverter.
Keywords
algorithm; induction machine; inverter; measurement; simulation
Hrčak ID:
174734
URI
Publication date:
10.2.2017.
Visits: 2.306 *