Review article
Lead content in the atmosphere of a storage battery factory
Katarina Mirnik
; Centralni higijenski zavod, Zagreb·
Abstract
Environmental conditions in a storage battery factory are described. The results of lead determination in air obtained in 1959 are compared with the results in 1949. In general all the results were 10-200 times above the permissible concentration Limits, and compared with the results obtained in 1949 a general increase of the number of high (14-30 mg/m3) results was established. Various improvements of working conditions are advised.
Keywords
Hrčak ID:
183010
URI
Publication date:
14.9.1959.
Visits: 1.115 *