Skip to the main content

Preliminary communication

https://doi.org/10.14256/JCE.1655.2016

Behaviour of 3D RC frames placed at different angles on shaking table

Fatih Bahadir
Fatih Süleyman Balik


Full text: croatian pdf 1.656 Kb

page 171-186

downloads: 390

cite

Full text: english pdf 1.670 Kb

page 171-186

downloads: 265

cite


Abstract

Behaviour of RC frames placed at different angles (biaxially) on the shaking table is analysed in the paper. The testing was conducted on four two-storey one-bay 3D RC frames scaled down to 1:6 of the original size, the aim being to analyse defects commonly observed on residential buildings. All specimens had infill walls and similar window openings. The specimens were subjected to sinusoidal dynamic testing. Test results show that different failure modes occurred at all specimens in the X and Y directions.

Keywords

reinforced-concrete frame; shaking table; dynamic testing; failure mode

Hrčak ID:

199516

URI

https://hrcak.srce.hr/199516

Publication date:

23.4.2018.

Article data in other languages: croatian

Visits: 1.569 *