Preliminary communication
https://doi.org/10.14256/JCE.2898.2020
Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis
Ali A. Muhsin
Hussam K. Risan
Full text: croatian pdf 3.551 Kb
page 1081-1092
downloads: 217
cite
APA 6th Edition
Muhsin, A.A. & Risan, H.K. (2021). Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis. Građevinar, 73 (11.), 1081-1092. https://doi.org/10.14256/JCE.2898.2020
MLA 8th Edition
Muhsin, Ali A. and Hussam K. Risan. "Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis." Građevinar, vol. 73, no. 11., 2021, pp. 1081-1092. https://doi.org/10.14256/JCE.2898.2020. Accessed 25 Dec. 2024.
Chicago 17th Edition
Muhsin, Ali A. and Hussam K. Risan. "Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis." Građevinar 73, no. 11. (2021): 1081-1092. https://doi.org/10.14256/JCE.2898.2020
Harvard
Muhsin, A.A., and Risan, H.K. (2021). 'Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis', Građevinar, 73(11.), pp. 1081-1092. https://doi.org/10.14256/JCE.2898.2020
Vancouver
Muhsin AA, Risan HK. Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis. Građevinar [Internet]. 2021 [cited 2024 December 25];73(11.):1081-1092. https://doi.org/10.14256/JCE.2898.2020
IEEE
A.A. Muhsin and H.K. Risan, "Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis", Građevinar, vol.73, no. 11., pp. 1081-1092, 2021. [Online]. https://doi.org/10.14256/JCE.2898.2020
Full text: english pdf 3.540 Kb
page 1081-1092
downloads: 288
cite
APA 6th Edition
Muhsin, A.A. & Risan, H.K. (2021). Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis. Građevinar, 73 (11.), 1081-1092. https://doi.org/10.14256/JCE.2898.2020
MLA 8th Edition
Muhsin, Ali A. and Hussam K. Risan. "Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis." Građevinar, vol. 73, no. 11., 2021, pp. 1081-1092. https://doi.org/10.14256/JCE.2898.2020. Accessed 25 Dec. 2024.
Chicago 17th Edition
Muhsin, Ali A. and Hussam K. Risan. "Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis." Građevinar 73, no. 11. (2021): 1081-1092. https://doi.org/10.14256/JCE.2898.2020
Harvard
Muhsin, A.A., and Risan, H.K. (2021). 'Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis', Građevinar, 73(11.), pp. 1081-1092. https://doi.org/10.14256/JCE.2898.2020
Vancouver
Muhsin AA, Risan HK. Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis. Građevinar [Internet]. 2021 [cited 2024 December 25];73(11.):1081-1092. https://doi.org/10.14256/JCE.2898.2020
IEEE
A.A. Muhsin and H.K. Risan, "Influence of near-fault characteristics on inelastic response of multi-storey building with intensity measurement analysis", Građevinar, vol.73, no. 11., pp. 1081-1092, 2021. [Online]. https://doi.org/10.14256/JCE.2898.2020
Abstract
This study is presented to achieve three objectives: (1) to compare between the inelastic responses of buildings under near and far fault excitations, (2) to investigate the effect of the pulse to structural period ratio, and (3) to evaluate a set of intensity measurements (IMs) in terms of near fault (NF) earthquakes. A real reinforced concrete building with 35 storeys is analysed in the scope of the first and second objectives, whereas the third objective involves three general-frame buildings consisting of 6, 13, and 20 storeys. Results show that the NF excitation can drive the building to exceed its life safety performance level. Furthermore, the accuracy of the IM highly depends on the vibration period of the building and the function used to calculate the IM.
Keywords
near-fault earthquakes, inelastic response, pulse period, intensity measurement
Hrčak ID:
269127
URI
https://hrcak.srce.hr/269127
Publication date:
27.12.2021.
Article data in other languages:
croatian
Visits: 1.463
*