Skip to the main content

Professional paper

https://doi.org/10.14256/JCE.2823.2019

Dynamic identification of three 19th century churches in Turkey

M. Bilal Bağbanci


Full text: croatian pdf 4.139 Kb

page 125-134

downloads: 130

cite

Full text: english pdf 4.138 Kb

page 125-134

downloads: 132

cite


Abstract

It is of great importance to determine the in-situ wall strength and dynamic characteristics of historic structures by experimental methods before structural analysis. The most effective experimental methods are the flat-jack, shear and vibration tests. After experimental methods, dynamic behaviour of the structures should be checked by the finite element analysis. Dynamic characteristics of three churches constructed in the 19th century in Balıkesir and Bursa provinces, now reduced to load-bearing walls (outer walls) only, are analysed in this study. It was established that, in order to identify dynamic characteristics of such structures, both the whole structure and the individual walls should be tested and evaluated by means of the finite element analysis.

Keywords

masonry structures; material tests; structural health monitoring; dynamic behaviour

Hrčak ID:

274890

URI

https://hrcak.srce.hr/274890

Publication date:

1.4.2022.

Article data in other languages: croatian

Visits: 681 *