Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.14256/JCE.3246.2021

Centrifugally-cast concrete poles with non-metallic reinforcement

Igor Džajić
Domagoj Damjanović
Goran Puž


Puni tekst: hrvatski pdf 3.696 Kb

str. 579-590

preuzimanja: 876

citiraj

Puni tekst: engleski pdf 3.692 Kb

str. 579-590

preuzimanja: 309

citiraj


Sažetak

The article describes the testing of poles for electric power transmission lines, which are made of centrifugally-cast concrete and ultra-high strength concrete, and which are prestressed with Carbon Fibre Reinforced Polymer tendons (CFRP). The presented results of pole ultimate load testing suggest the potential for usage of this construction product, particularly in aggressive environments with high probability of steel corrosion. Part of the tested poles had shear reinforcement in the form of confined Glass Fibre Reinforced Polymer (GFRP) grid, while one share of samples had no shear reinforcement, but the concrete matrix was strengthened with synthetic macro fibres. A review is given on similar product testing, calculation methods, and guidance is provided for further research.

Ključne riječi

non-metallic reinforcement; Carbon Fibre Reinforced Polymer (CFRP); centrifugally-cast poles; prestressing; ultimate load testing; bending testing

Hrčak ID:

260818

URI

https://hrcak.srce.hr/260818

Datum izdavanja:

22.7.2021.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.161 *