Skoči na glavni sadržaj

Izvorni znanstveni članak

Influence of wall girder size on its bearing capacity and ductility

Željko Smolčić
Joško Ožbolt
Darko Meštrović


Puni tekst: hrvatski pdf 1.135 Kb

str. 1031-1041

preuzimanja: 545

citiraj


Sažetak

Results obtained by determining, through shear stress analysis, the influence of size of wall girders without reinforcement on their bearing capacity and ductility are presented. The program for non-linear analysis of concrete structures, based on the finite-element method, was used. The analysis was conducted for three different percentages of reinforcement aimed at countering the bending action. This analysis has shown that the nominal bearing capacity and ductility reduce with the increase in size. It is stressed that this reduction of nominal capacity is not significant for engineering practice.

Ključne riječi

wall girder; influence of wall girder size; bearing capacity; ductility; nonlinear analysis; finite-element method

Hrčak ID:

32401

URI

https://hrcak.srce.hr/32401

Datum izdavanja:

29.1.2009.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.862 *