Skoči na glavni sadržaj

Prethodno priopćenje

Theoretical determination of elasticity constants for steam boiler membrane wall as the structurally orthotropic plate

Josip Sertić ; Mechanical Engineering Faculty in Slavonski Brod, Josip Juraj Strossmayer University of Osijek, Trg I. B. Mažuranić 2, HR-35000 Slavonski Brod, Republic of Croatia
Ivan Gelo ; Mechanical Engineering Faculty in Slavonski Brod, Josip Juraj Strossmayer University of Osijek, Trg I. B. Mažuranić 2, HR-35000 Slavonski Brod, Republic of Croatia
Dražan Kozak orcid id orcid.org/0000-0001-5245-4686 ; Mechanical Engineering Faculty in Slavonski Brod, Josip Juraj Strossmayer University of Osijek, Trg I. B. Mažuranić 2, HR-35000 Slavonski Brod, Republic of Croatia
Darko Damjanović orcid id orcid.org/0000-0002-7341-6029 ; Mechanical Engineering Faculty in Slavonski Brod, Josip Juraj Strossmayer University of Osijek, Trg I. B. Mažuranić 2, HR-35000 Slavonski Brod, Republic of Croatia
Pejo Konjatić ; Mechanical Engineering Faculty in Slavonski Brod, Josip Juraj Strossmayer University of Osijek, Trg I. B. Mažuranić 2, HR-35000 Slavonski Brod, Republic of Croatia


Puni tekst: hrvatski pdf 2.451 Kb

str. 697-703

preuzimanja: 605

citiraj

Puni tekst: engleski pdf 2.451 Kb

str. 697-703

preuzimanja: 952

citiraj


Sažetak

This paper presents theoretical determination of elasticity constants for steam boiler membrane wall as structurally orthotropic plate. Modulus of elasticity and shear modulus are determined in directions parallel and perpendicular to membrane wall pipes for both bending and membrane load. When determining modulus of elasticity for bending load, Engesser's theorem is used for obtaining deflection of membrane wall. After that, from equality of deflections of membrane wall and structurally orthotropic plate, modulus of elasticity is obtained. When determining modulus of elasticity for membrane load, Engesser's theorem is also used, and the expression is obtained from extension equation of membrane wall and structurally orthotropic plate. Shear moduli for both loading conditions are obtained using Poisson's ratios.

Ključne riječi

elasticity constants; membrane wall; steam boiler; structurally orthotropic plate

Hrčak ID:

106703

URI

https://hrcak.srce.hr/106703

Datum izdavanja:

21.8.2013.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.856 *