Skip to the main content

Original scientific paper

https://doi.org/10.17559/TV-20170331003443

Application of a Simplified PLL Algorithm for Unbalanced Three Phase Systems by Using Low Cost Microcontrollers

Mustafa Cem Ozkilic orcid id orcid.org/0000-0001-9369-984X ; Yildiz Technical University, Faculty of Electrical and Electronics, Department of Electrical Engineering, Davutpasa Campus, Esenler, İstanbul, Turkey
Atiye Hulya Obdan orcid id orcid.org/0000-0002-6578-0293 ; Yildiz Technical University, Faculty of Electrical and Electronics, Department of Electrical Engineering, Davutpasa Campus, Esenler, İstanbul, Turkey


Full text: english pdf 1.255 Kb

page 94-98

downloads: 1.529

cite


Abstract

In literature, there are many Phased Locked Loop (PLL) methods achieving grid matching successfully under unbalanced grid conditions. However, these methods require high computational resources. In this article, a simplified PLL algorithm has been used with fixed point arithmetic for detecting phase and magnitude of an unbalanced three phase system. The simplification factor comes from the fact that an easy to implement low pass filtering algorithm has been implemented in a 16 bit microcontroller operating at 20 MHz clock speed. Sampling frequency has been selected as 20 kHz so that a low cost grid connected inverter operating up to 20 kHz switching frequency can be designed.

Keywords

Multiple Reference Frame Phased Locked Loop; Phase Locked Loop; Synchronous Reference Frame Phased Locked Loop; Unbalanced Three Phase Voltages

Hrčak ID:

200603

URI

https://hrcak.srce.hr/200603

Publication date:

26.5.2018.

Visits: 2.398 *