Stručni rad
https://doi.org/10.2478/10004-1254-64-2013-2256
Revizija rasporeda zamjene filtara respiratora za zaštitu od organskih para u pogonu za proizvodnju boj
Ali Karimi
; Department of Occupational Health, School of Public Health and Nutrition, Shiraz University of Medical Sciences, Shiraz, Iran
Mehdi Jahangiri
; Department of Occupational Health, School of Public Health and Nutrition, Shiraz University of Medical Sciences, Shiraz, Iran
Forough Zare Derisi
; Department of Occupational Health, School of Public Health and Nutrition, Shiraz University of Medical Sciences, Shiraz, Iran
Mohammad Amin Nourozi
; Department of Occupational Health, School of Public Health and Nutrition, Shiraz University of Medical Sciences, Shiraz, Iran
Sažetak
Nakon revizije rasporeda zamjene filtara respiratora u pogonu za proizvodnju boja u Iranu utvrđeno je da postojeći raspored ne pruža odgovarajuću zaštitu od organskih para na pojedinim radnim mjestima te da ga treba skratiti s postojećih 48 h do 72 h na 4 h. Revizijom je također utvrđeno da vrijeme zamjene filtara na temelju osjeta mirisa nije djelotvorno te da se za utvrđivanje rasporeda zamjene filtara i njegovu prilagodbu pojedinomu radnomu mjestu može primijeniti računalni program za određivanje vijeka trajanja fi ltra MultiVapor koji je osmislio američki Nacionalni institut za sigurnost na radu i medicinu rada (National Institute for Occupational Safety and Health, krat. NIOSH).
Ključne riječi
kemijski filtar; prag mirisa; vijek trajanja filtra
Hrčak ID:
98694
URI
Datum izdavanja:
20.3.2013.
Posjeta: 2.294 *