Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.5599/admet.782

Validated HPLC method for quantification of copanlisib in mice plasma: application to a pharmacokinetic study

Ashok Zakkula ; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore-560 022, India
Pavan Kumar Kurakula ; Department of Pharmacology, Raghavendra Institute of Pharmaceutical Education and Research, Anantapur-515721, A.P, India
Sreekanth Dittakavi ; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore-560 022, India
Prasanthi Daram ; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore-560 022, India
Ram Murthi Bestha ; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore-560 022, India
Mohd Zainuddin ; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore-560 022, India
Ravi Kumar Trivedi ; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore-560 022, India
Ramesh Mullangi orcid id orcid.org/0000-0003-1359-8999 ; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore-560 022, India


Puni tekst: engleski pdf 651 Kb

str. 113-121

preuzimanja: 480

citiraj


Sažetak

Copanlisib is a pan phosphatidylinositol 3-kinase (PI3K) inhibitor approved for follicular lymphoma. In this paper, we present the data of development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of copanlisib in mice plasma as per the FDA regulatory guideline. The method involves the extraction of copanlisib along with internal standard (IS, enasidenib) from mice plasma (100 µL) using ethyl acetate as an extraction solvent. The chromatographic resolution of copanlisib and the IS was achieved on a Hypersil Gold C18 column maintained at 40 °C using a binary gradient mobile phase [10 mM ammonium formate (pH 4.0) and acetonitrile]. The flow-rate was 0.8 mL/min. For the detection of copanlisib and the IS, the photo-diode array detector was set at λmax 310 nm. Copanlisib and the IS eluted at 6.60 and 7.80 min, respectively with a total run time of 10 min. The calibration curve was linear over a concentration range of 50 to 5000 ng/mL for copanlisib (r2 0.998). The results of intra- and inter-day accuracy and precision studies were within the acceptable limits. Copanlisib was stable on bench-top, in auto-sampler, up to three freeze/thaw cycle and long-term storage at -80 °C. The application of the validated method was shown in a mice pharmacokinetic study.

Ključne riječi

Copanlisib; HPLC; method validation; mice plasma; pharmacokinetics

Hrčak ID:

235016

URI

https://hrcak.srce.hr/235016

Datum izdavanja:

4.3.2020.

Posjeta: 1.367 *