Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.15644/asc55/3/1

Comparison of Osteoimmunological and Microbiological Parameters of Extra Short and Longer Implants Loaded in the Posterior Mandible: A Split Mouth Randomized Clinical Study

Bilge Karci orcid id orcid.org/0000-0003-0351-4894 ; Zavod za parodontologiju Fakulteta dentalne medicine Sveučilišta Alanya Alaaddin Keykubat, Alanya, Antalija, Turska *
Elif Oncu ; Zavod za parodontologiju Fakulteta dentalne medicine Sveučilišta Necmettin Erbakan, Konya, Turska

* Dopisni autor.


Puni tekst: engleski pdf 253 Kb

str. 238-247

preuzimanja: 476

citiraj

Puni tekst: hrvatski pdf 253 Kb

str. 238-247

preuzimanja: 189

citiraj


Sažetak

Objectives: This study aimed to evaluate the levels of TNF-α, PGE2, RANKL, RANK, OPG, the markers of periimplant bone loss in peri-implant crevicular fluid obtained around standard and extra short implants. Moreover, the levels of putative oral pathogens were investigated in the submucosal biofilm samples. Material and Methods: The implants were divided into two groups according to their lengths: standard (≥8 mm) and extra short (4 mm). A total of 60 implants were researched in 30 patients. The probing depth (PD), clinical attachment level (CAL), presence of bleeding on probing (BOP), 3-year survival rate (CSR), and bone loss (BL) were measured. Results: No statistically significant difference was found in the values of PD, CAL, BOP, CSR, and BL between the groups (P> 0.05). Total amounts of PGE2, TNF-α, RANKL, RANK, OPG, and RANKL/OPG were not statistically significantly different between the groups (P> 0.05). The abundance of F. nucleatum, T. forsythia, P. intermedia, P. gingivalis, S. oralis and T. denticola was compared between the groups and the results were not statistically significant (P> 0.05). Conclusion: The results of this study suggested that PGE2, TNF-α, RANKL, RANK, OPG, and RANKL/OPG in PICF, as well as microbiological parameters in submucosal
biofilms, were similar between standard (≥8 mm) and extra short (4 mm) implants. Therefore, the implant length does not seem to influence the bone loss, levels of osteoimmunological and microbiological markers in the peri-implant tissues and survival rates.

Ključne riječi

MeSH terms: Dental Implantation; Osseointegration; Bone-Implant Interface; Biofilms; Dental Implants;

Hrčak ID:

262368

URI

https://hrcak.srce.hr/262368

Datum izdavanja:

22.9.2021.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.488 *