Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.13167/2024.28.3

Comparative probability-based seismic safety assessment of base-isolated buildings: A case study

Peyman Narjabadifam ; University of Bonab, Faculty of Engineering, Department of Civil Engineering, Velayat Highway, 5551395133, Bonab, East Azerbaijan, Iran
Somayeh Mollaei orcid id orcid.org/0000-0001-6592-179X ; University of Bonab, Faculty of Engineering, Department of Civil Engineering, Velayat Highway, 5551395133, Bonab, East Azerbaijan, Iran
Ehsan Noroozinejad Farsangi ; Western Sydney University, Urban Transformations Research Centre (UTRC), NSW, Australia *
Mehdi Babaei ; University of Bonab, Faculty of Engineering, Department of Civil Engineering, Velayat Highway, 5551395133, Bonab, East Azerbaijan, Iran
Navid Mousavi ; University of Bonab, Faculty of Engineering, Department of Civil Engineering, Velayat Highway, 5551395133, Bonab, East Azerbaijan, Iran

* Dopisni autor.


Puni tekst: engleski PDF 556 Kb

str. 33-49

preuzimanja: 181

citiraj


Sažetak

Seismic fragility curves are used to assess the structural vulnerability probability at various damage states. In this study, the effects of different isolation systems on the seismic safety of a two-dimensional reinforced concrete moment-resisting frame are investigated. The reference structure was a hotel building in California, USA. A comparative probability-based seismic safety assessment for building components was conducted on the superstructure hypothetically fitted with various isolation systems. In this regard, two categories of isolation systems, including rubber‐ and friction‐based systems, were selected. The high damping rubber bearings and friction pendulum systems were considered. Incremental dynamic analyses were conducted for a suite of earthquake records to develop the fragility curves considering modelling, demand, and capacity uncertainties. Based on the results, it was observed that the building failure probability reduction was influenced by the seismic isolation systems rather than the fixed base (un-retrofitted) model. Furthermore, the high damping rubber bearings system was found to be more reliable than the friction pendulum system in the limit states considered. However, no significant discrepancy was observed in the performance of the building fitted with isolation systems at higher damage states.

Ključne riječi

fragility curve; seismic isolation; damage state; incremental dynamic analysis