hrcak mascot   Srce   HID

Professional paper

Variation of vascular ring as a cause of extubation failure

IVANCICA SKARIC ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia
JASMINKA JAKOBOVIC ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia
MAJA KARAMAN ILIC ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia
KARMEN KONDZA ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia
IRENA BABIC ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia

Fulltext: english, pdf (177 KB) pages 29-31 downloads: 503* cite
APA 6th Edition
SKARIC, I., JAKOBOVIC, J., KARAMAN ILIC, M., KONDZA, K. & BABIC, I. (2008). Variation of vascular ring as a cause of extubation failure. Signa vitae, 3 (2), 29-31. Retrieved from https://hrcak.srce.hr/28698
MLA 8th Edition
SKARIC, IVANCICA, et al. "Variation of vascular ring as a cause of extubation failure." Signa vitae, vol. 3, no. 2, 2008, pp. 29-31. https://hrcak.srce.hr/28698. Accessed 25 Sep. 2021.
Chicago 17th Edition
SKARIC, IVANCICA, JASMINKA JAKOBOVIC, MAJA KARAMAN ILIC, KARMEN KONDZA and IRENA BABIC. "Variation of vascular ring as a cause of extubation failure." Signa vitae 3, no. 2 (2008): 29-31. https://hrcak.srce.hr/28698
Harvard
SKARIC, I., et al. (2008). 'Variation of vascular ring as a cause of extubation failure', Signa vitae, 3(2), pp. 29-31. Available at: https://hrcak.srce.hr/28698 (Accessed 25 September 2021)
Vancouver
SKARIC I, JAKOBOVIC J, KARAMAN ILIC M, KONDZA K, BABIC I. Variation of vascular ring as a cause of extubation failure. Signa vitae [Internet]. 2008 [cited 2021 September 25];3(2):29-31. Available from: https://hrcak.srce.hr/28698
IEEE
I. SKARIC, J. JAKOBOVIC, M. KARAMAN ILIC, K. KONDZA and I. BABIC, "Variation of vascular ring as a cause of extubation failure", Signa vitae, vol.3, no. 2, pp. 29-31, 2008. [Online]. Available: https://hrcak.srce.hr/28698. [Accessed: 25 September 2021]

Abstracts
We report on an unexpected extubation failure in a two year old boy. In our patient, failure of extubation led to a diagnostic examination. The result of our examination was discovery of a congenital anomaly of the aortic arch and great vessels (vascular ring) with compression of the trachea. The presence of this anomaly in this patient was unknown to us before. A successful surgical procedure eliminated the underlying cause of the persistent extubation failures.