Skoči na glavni sadržaj

Stručni rad

An Unusual Cause of Recurrent Laryngeal Nerve Monitoring Failure during Parathyroidectomy

TOBY N. WEINGARTEN ; Assistant Professor of Anesthesiology From the Department of Anesthesiology and Department of Surgery College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905
KATARINA BOJANIĆ ; Resident in Pediatrics (Research Trainee at Mayo Clinic)
AMANDA R. MORASKA ; Mayo Clinic Medical Student
JURAJ SPRUNG ; Professor of Anesthesiology
GEOFFREY B. THOMPSON ; Professor of Surgery


Puni tekst: engleski pdf 63 Kb

str. 86-88

preuzimanja: 553

citiraj


Sažetak

Intraoperative monitoring of the recurrent laryngeal nerve (RLN) during surgical dissection allows for real time identification and assessment of nerve function integrity. Since neuromuscular blockade interferes with electromyography, long-acting muscle relaxants cannot be used during anesthesia. We report a patient in whom monitoring of the RLN was unsuccessful because of prolonged muscle paralysis following the administration of succinylcholine, presumably due to a pseudocholinesterase deficiency.

Ključne riječi

laryngeal nerve monitoring; muscle paralysis; pseudocholinesterase deficiency

Hrčak ID:

73173

URI

https://hrcak.srce.hr/73173

Datum izdavanja:

1.10.2011.

Posjeta: 910 *