Izvorni znanstveni članak
COD Fractions in Sewage Flowing into Polish Sewage Treatment Plants
Z. Sadecka
; University of Zielona Góra, Institute of Environmental Engineering Poland, 65-516 Zielona Góra, ul. Prof. Z. Szafrana 15
A. Jedrezak
; University of Zielona Góra, Institute of Environmental Engineering Poland, 65-516 Zielona Góra, ul. Prof. Z. Szafrana 15
E. P³uciennik-Koropczuk
; University of Zielona Góra, Institute of Environmental Engineering
S. Myszograj
; University of Zielona Góra, Institute of Environmental Engineering
M. Suchowska-Kisielewicz
; University of Zielona Góra, Institute of Environmental Engineering
Sažetak
The paper presents the results of studies concerning the designation of COD fraction in raw wastewater. The research was conducted in three mechanical-biological sewage treatment plants. The results were compared with data assumed in the ASM models. During the investigation, the following fractions of COD were determined: dissolved non-biodegradable SI, dissolved easily biodegradable SS, in organic suspension slowly degradable XS, and in organic suspension non-biodegradable XI. The methodology fordetermining the COD fraction was based on the ATV- A 131guidelines. The real concentration of fractions in raw wastewater and the percentage of each fraction in total CODare different from data reported in the literature.
Ključne riječi
COD fractions; raw wastewater; ASM models
Hrčak ID:
104798
URI
Datum izdavanja:
1.7.2013.
Posjeta: 1.329 *