Skip to the main content

Preliminary communication

Strength and ductility of concrete confined circular columns

Dušan Najdanović
Branko Milosavljević


Full text: croatian pdf 387 Kb

page 417-423

downloads: 1.974

cite

Full text: english pdf 380 Kb

page 417-432

downloads: 2.410

cite


Abstract

The design procedure of capacity and ductility on the concrete columns with circular cross section depending on the amount of the confining reinforcement is presented in this paper. The stress-strain model in which the longitudinal compressive strain of the concrete at failure is corresponding to the first fracture of the transverse reinforcement, is presented. The cross section capacity and the ductility factor corresponding to the longitudinal force and stirup distance is analyzed. Use of the similar design procedure on concrete-filled steel tubular columns and in strengthening of columns using still straps or FRP is possible.

Keywords

circular columns; transverse reinforcement; limit bearing capacity; curvature; ductility

Hrčak ID:

122575

URI

https://hrcak.srce.hr/122575

Publication date:

10.6.2014.

Article data in other languages: croatian

Visits: 5.441 *