Skip to the main content

Professional paper

Comparison of 23 Gauge and 25 Gauge PPV in the Treatment of Epiretinal Membranes and Macular Holes

Damir Kovačević ; Department of Ophthalmology, Clinical Hospital Center Rijeka, Rijeka, Croatia
Ivana Valković Antić ; Department of Ophthalmology, Clinical Hospital Center Rijeka, Rijeka, Croatia
Aldo Valković ; Department of Ophthalmology, Clinical Hospital Center Rijeka, Rijeka, Croatia


Full text: english pdf 832 Kb

page 1213-1216

downloads: 278

cite


Abstract

The aim of this study was to show the long term recovery after the operative procedure of pars plana vitrectomy (PPV)
in patients with epiretinal membranes (ERM) and macular holes. We wanted to show if there is a difference in operative
approach and results of 23 and 25 gauge PPV. Twenty eight patients underwent to operative treatment of idiopatic ERM
and macular holes grade III and IV. In our study there was not a statistical signifi cant difference in visual acuity (VA)
between 23 gauge and 25 gauge operated patients, both ERM and macular holes. Although both approaches are good,
morphological restitution do not always follow the functional recovery.

Keywords

vitrectomy; gauge; epiretinal membranes; macular holes; visual acuity

Hrčak ID:

147439

URI

https://hrcak.srce.hr/147439

Publication date:

26.12.2014.

Visits: 858 *