Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.15644/asc50/1/2

Cytotoxicity of Two Bioactive Root Canal Sealers

Anja Baraba ; Zavod za endodonciju i restaurativnu stomatologiju Stomatološkog fakulteta Sveučilišta u Zagrebu, Zagreb, Hrvatska
Sonja Pezelj-Ribarić ; Katedra za oralnu medicinu i parodontologiju Studija dentalne medicine Medicinskog fakulteta Sveučilišta u Rijeci, Rijeka, Hrvatska
Marija Roguljić ; Stomatološka poliklinika Split, Split, Hrvatska
Ivana Miletić ; Zavod za endodonciju i restaurativnu stomatologiju Stomatološkog fakulteta Sveučilišta u Zagrebu, Zagreb, Hrvatska


Puni tekst: hrvatski pdf 219 Kb

str. 8-13

preuzimanja: 475

citiraj

Puni tekst: engleski pdf 219 Kb

str. 8-13

preuzimanja: 614

citiraj


Sažetak

Objective: The aim of this study was to investigate the cytotoxicity of two different bioactive root canal sealers: one based on mineral trioxide aggregate, MTA Fillapex (Angelus, Solucoes Odontologicas,
Londrina, PR, Brazil), and the other based on bioceramics, Endosequence BC Sealer (Brasseler, Savannah, Georgia, USA), in culture of mouse L929 fibroblasts. Materials and methods: Mouse fibroblasts (L929), obtained from subcutaneous connective tissue of mouse line C3Hf, were cultivated in plastic culture flasks in an incubator at 37ºC, with 5% CO2 and 90% humidity. Freshly mixed Endosequence BC Sealer and MTA Fillapex (0.1 g each) were placed on sterile teflon discs, 6 mm in diameter. Teflon discs with the materials as well as empty discs serving as control were placed in wells of 12-well plate. After incubation times of 1, 6, 20 and 24 hours, the teflon discs were removed from the wells and the number of viable cells was determined using trypan blue in Neubauer chamber. Results: In comparison to the control group, MTA Fillapex had significantly less viable cells for all incubation periods (p≤0.05), while Endosequence BC sealer had significantly less viable cells after 6, 20,
and 24 hours of incubation (p≤0.05). MTA Fillapex exhibited ignificantly less viable cells in comparison to Endosequence BC sealer after the first hour and after 20 hours of incubation (p≤0.05), while for the other incubation periods there were no significant differences (p≥0.05). Conclusion: MTA Fillapex and Endosequence BC sealer were both cytotoxic in cultures of mouse L929 fibroblasts.

Ključne riječi

Root Canal Filling Materials; Aluminium Compounds; Calcium Compounds; Toxicity Tests

Hrčak ID:

154342

URI

https://hrcak.srce.hr/154342

Datum izdavanja:

17.3.2016.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.004 *