Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.15644/asc50/1/6

Titanium Ions Release from an Innovative Titanium-Magnesium Composite: an in Vitro Study

Zlatko Stanec orcid id orcid.org/0000-0002-7704-6950 ; Ordinacija dentalne medicine, Samobor, Hrvatska
Jasna Halambek ; Zavod za opću i organsku kemiju Veleučilišta u Karlovcu, Karlovac, Hrvatska
Krešimir Maldini ; Hrvatske vode, Glavni vodnogospodarski laboratorij, Zagreb, Hrvatska
Martin Balog ; Institut za materijale i mehaniku strojeva Slovačke akademije znanosti, Bratislava, Slovačka
Peter Križik ; Institut za materijale i mehaniku strojeva Slovačke akademije znanosti, Bratislava, Slovačka
Zdravko Schauperl ; Fakultet strojarstva i brodogradnje Sveučilišta u Zagrebu, Zagreb, Hrvatska
Amir Ćatić ; Stomatološki fakultet Sveučilišta u Zagrebu, Zagreb, Hrvatska


Puni tekst: hrvatski pdf 578 Kb

str. 40-48

preuzimanja: 509

citiraj

Puni tekst: engleski pdf 578 Kb

str. 40-48

preuzimanja: 581

citiraj


Sažetak

The innovative titanium-magnesium composite (Ti-Mg) was produced by powder metallurgy (P/M) method and is characterized in terms of corrosion behavior. Material and methods: Two groups of experimental material, 1 mass% (Ti-1Mg) and 2 mass% (Ti-2Mg) of magnesium in titanium matrix, were tested and compared to commercially pure titanium (CP Ti). Immersion test and chemical analysis of four solutions: artificial saliva; artificial saliva pH 4; artificial saliva with fluoride and Hank balanced salt solution were performed after 42 days of immersion, using inductively coupled plasma mass spectrometry (ICP-MS) to detect the amount of released titanium ions (Ti). SEM and EDS analysis were used for surface characterization. Results: The difference between the results from different test solutions was assessed by ANOVA and Newman-Keuls test at p<0.05. The influence of predictor variables was found by multiple regression analysis. The results of the present study revealed a low corrosion rate of titanium from the experimental Ti-Mg group. Up to 46 and 23 times lower dissolution of Ti from Ti-1Mg and Ti-2Mg, respectively was observed compared to the control group. Among the tested solutions, artificial saliva with fluorides exhibited the highest corrosion effect on all specimens tested. SEM micrographs showed preserved dual phase surface structure and EDS analysis suggested a favorable surface bioactivity. Conclusion: In conclusion, Ti-Mg produced by P/M as a material with better corrosion properties when compared to CP Ti is suggested.

Ključne riječi

Titanium; Magnesium; Corrosion; Immersion; Saliva, Artificial; Ion Exchange

Hrčak ID:

154346

URI

https://hrcak.srce.hr/154346

Datum izdavanja:

17.3.2016.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.960 *