Tehnički vjesnik, Vol. 23 No. 6, 2016.
Izvorni znanstveni članak
https://doi.org/10.17559/TV-20150519103549
Storage tank for a single-person household providing same flow conditions as for calibration measurements by water meter
Lajos Hovány
orcid.org/0000-0002-3378-0600
; University of Novi Sad, Faculty of Civil Engineering Subotica, Kozaračka 2a, 24000 Subotica, Serbia
Sažetak
In order to ensure the same conditions as for flow calibration, in case of a single-person household provided with a class B multi-jet propeller water meter with nominal diameter of 20 mm, a thermally insulated storage tank was built. During the exploitation, the storage tank will be fed by calibrated constant discharges in stages. For the purposes of measured consumption cumulative curve, the needed tank volume, flow rate and minimum duration of the filling stage were defined in the function of water meter reading accuracy (1 litre, 0,1 litre and 0,025 litre). The measurements proved that the thermally insulated tanks were able to keep water temperature within the range identical to that measured in the water supply in a single-person household.
Ključne riječi
single-person household; storage tank; water meter calibration; water meter reading accuracy; water temperature
Hrčak ID:
169358
URI
Datum izdavanja:
29.11.2016.
Posjeta: 2.255 *