Tehnički vjesnik, Vol. 24 No. 1, 2017.
Izvorni znanstveni članak
https://doi.org/10.17559/TV-20130502140334
Reliability analysis of multiplex control system of subsea blowout preventer based on stochastic Petri net
Zengkai Liu
; China University of Petroleum, College of Mechanical and Electronic Engineering, Qingdao, Shandong Province, China
Yonghong Liu
; China University of Petroleum, College of Mechanical and Electronic Engineering, Qingdao, Shandong Province, China
Baoping Cai
; China University of Petroleum, College of Mechanical and Electronic Engineering, Qingdao, Shandong Province, China
Ju Li
; China University of Petroleum, College of Mechanical and Electronic Engineering, Qingdao, Shandong Province, China
Xiaojie Tian
; China University of Petroleum, College of Mechanical and Electronic Engineering, Qingdao, Shandong Province, China
Sažetak
The multiplex (MUX) control system of subsea blowout preventer (BOP) plays a vital role in providing safe working conditions for the subsea drilling activities. According to the working states and critical failure modes of the MUX control system, this paper presents its stochastic Petri nets (SPN) model, taking into account the imperfect fault detection capacity. The numerical analysis method is proposed based on the isomorphic continuous-time Markov chain of the model. The reliability indexes, namely reliability, availability and MTTF of the MUX control system and pilot hydraulic control system are obtained and compared. In addition, the effects of fault coverage factor on state probabilities and availability of the MUX control system are researched and the uncertainty analysis of the firing rates related to MTTF is also performed.
Ključne riječi
availability; multiplex control system; reliability; Stochastic Petri nets; subsea blowout preventer
Hrčak ID:
174694
URI
Datum izdavanja:
10.2.2017.
Posjeta: 3.356 *