Environmental conditions in a storage battery factory are described. The results of lead determination in air obtained in 1959 are compared with the results in 1949. In general all the results were 10-200 times above the permissible concentration Limits, and compared with the results obtained in 1949 a general increase of the number of high (14-30 mg/m3) results was established. Various improvements of working conditions are advised.