Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.11613/BM.2017.039

Labile glycated haemoglobin and carbamylated haemoglobin are still critical points for HbA1c measurement

Aurore Desmons ; Laboratory of Pediatric Biology and Research, University Hospital of Reims, Reims, France
Stéphane Jaisson ; Laboratory of Pediatric Biology and Research, University Hospital of Reims, Reims, France
Nathalie Leroy ; Laboratory of Pediatric Biology and Research, University Hospital of Reims, Reims, France
Philippe Gillery ; Laboratory of Pediatric Biology and Research, University Hospital of Reims, Reims, France
Emmanuelle Guillard ; Laboratory of Pediatric Biology and Research, University Hospital of Reims, Reims, France


Puni tekst: engleski pdf 977 Kb

str. 378-386

preuzimanja: 322

citiraj


Sažetak

IntroductionHaemoglobin A1c (HbA1c) is a key analyte for the monitoring of glycemic balance in diabetic patients and is used for diabetes diagnosis in many countries. The potential interference of carbamylated haemoglobin (cHb) and labile glycated haemoglobin (LA1c) on HbA1c assays must remain a matter of vigilance. Such a situation has occurred in our laboratory with a kit replacement on the Bio-Rad Variant™ II testing system, a cation-exchange high performance liquid chromatography (HPLC) system. With this method, LA1c and cHb coeluted in a same peak which may have different consequences on HbA1c values. Materials and methodsThe influence of increasing LA1c and cHb values on HbA1c results was studied with in vitro glycation and carbamylation of samples. Samples from patients with high and normal blood urea concentrations were assayed by HPLC and immunological assay. ResultsWe observed that the degree of interference greatly varied depending on the nature of the interfering Hb fractions found under the so-called “LA1c peak”. Thus, we have decided to apply a decision tree using “LA1c” thresholds depending on: (i) the retention time, (ii) the shape of the peak, (iii) other analytes, like urea. If the peak recognized as “LA1c” is mainly formed by LA1c, we consider that there is no interference until 4%. If the peak is mainly formed by cHb, we consider an interference threshold equal to 2%. ConclusionsThis situation reminds that cHb and LA1c remain critical issues in chromatography-based HbA1c assays and that adapted criteria must be set up for result interpretation.

Ključne riječi

carbamylated haemoglobin; labile glycated haemoglobin; HbA1c; analytical interference

Hrčak ID:

183388

URI

https://hrcak.srce.hr/183388

Datum izdavanja:

15.6.2017.

Posjeta: 1.005 *