Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.15255/CABEQ.2016.1017

Comparison of Hexane Vapour Permeation in Two Different Polymeric Membranes via an Innovative In-line FID Detection Method

Z. Petrusová ; Institute of Chemical Process Fundamentals of the CAS, v.v.i., Rozvojová 135, 165 02 Prague 6, Czech Republic
L. Morávková ; Institute of Chemical Process Fundamentals of the CAS, v.v.i., Rozvojová 135, 165 02 Prague 6, Czech Republic
J. Vejražka ; Institute of Chemical Process Fundamentals of the CAS, v.v.i., Rozvojová 135, 165 02 Prague 6, Czech Republic
Z. Vajglová ; Institute of Chemical Process Fundamentals of the CAS, v.v.i., Rozvojová 135, 165 02 Prague 6, Czech Republic
J. C. Jansen orcid id orcid.org/0000-0003-4538-6851 ; Institute on Membrane Technology, ITM-CNR, Via P. Bucci 17/C, 87036 Rende (CS), Italy
P. Izák orcid id orcid.org/0000-0001-7364-3646 ; Institute of Chemical Process Fundamentals of the CAS, v.v.i., Rozvojová 135, 165 02 Prague 6, Czech Republic


Puni tekst: engleski pdf 797 Kb

str. 145-160

preuzimanja: 524

citiraj


Sažetak

This manuscript presents a novel method for the analysis of vapour permeation through polymeric membranes based on in-line analysis of the permeate with an FID detector. The hexane vapour permeation was studied for two commercially available membranes, namely low-density polyethylene (LDPE) and thin-film-composite polyamide
(PA) membrane. The hexane permeation was studied at temperatures of 25–45 °C, hexane vapour activity in the range of 0.2–0.8 and trans-membrane pressures of 5–50 kPa. Two fundamentally different membranes were chosen to demonstrate the potential and sensitivity of the permeation apparatus. Upon increasing the temperature from 25 to 45 °C, the flux in LDPE was found to increase almost fourfold over the whole activity range. The nonlinear increase of the flux with activity indicates plasticization of the polymer by hexane. Contrarily, the flux in the PA membrane increases almost linearly with activity, with only a minor upward curvature. Since the PA is far away from any phase transition, it is less temperature-dependent than LDPE. The activation energy for permeation demonstrates that the temperature dependence in the LDPE membrane is dominated by changes in diffusion, whereas it is dominated by changes in solubility in the PA membrane.







This work is licensed under a Creative Commons Attribution 4.0 International License.

Ključne riječi

sensitive permeation apparatus; low-density polyethylene; thin-film-composite membrane; gas/vapour separation; hexane permeation; in-line FID detection

Hrčak ID:

183941

URI

https://hrcak.srce.hr/183941

Datum izdavanja:

7.7.2017.

Posjeta: 1.074 *