Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.17559/TV-20150125105926

Innovation of parameter αcc for design resistance of high-strength concrete columns

Radmila Sinđić-Grebović orcid id orcid.org/0000-0002-8301-5691 ; University of Montenegro, Faculty of Civil Engineering, Bul. Džordža Vašingtona bb, 81000 Podgorica, Montenegro
Željka Radovanović ; University of Montenegro, Faculty of Civil Engineering, Bul. Džordža Vašingtona bb, 81000 Podgorica, Montenegro


Puni tekst: hrvatski pdf 1.173 Kb

str. 1449-1456

preuzimanja: 510

citiraj

Puni tekst: engleski pdf 1.173 Kb

str. 1449-1456

preuzimanja: 808

citiraj


Sažetak

The usage of high-strength concrete has been increased significantly in recent decades. By increasing the compressive strength of concrete, stress-strain features of concrete are changed. In contemporary technical regulations specific provisions for high-strength concrete are proposed. EN 1992-1-1 comprises concretes to the class C90/105. According to EN 1992-1-1 reduction factor for value of concrete compressive strength for design αcc, depends on two parameters, none of which compressive strength of concrete. Test results have shown that calculation of bearing capacity of columns, with recommended αcc and curved-rectangular stress block is non-conservative for high-strength concrete. It was shown that coefficient αcc should be redefined by introducing of new parameter which will cover differences of less design strength for high strength concrete. In many countries value of 0,85 is used for αcc, as proposed in their National Documents. Correlation between calculated capacity of columns and experimental results was used for its redefining.

Ključne riječi

column; design compressive strength; EN 1992-1-1; high-strength concrete; parameter αcc

Hrčak ID:

188242

URI

https://hrcak.srce.hr/188242

Datum izdavanja:

25.10.2017.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.582 *