Tehnički vjesnik, Vol. 25 No. 2, 2018.
Izvorni znanstveni članak
https://doi.org/10.17559/TV-20160203223352
Improved Method for Long-Term Frequency Stability Measurement Using Vector Voltmeter
Ivica Milanovic
orcid.org/0000-0001-7494-3755
; Technical Test Center, Vojvode Stepe 445A, 11000 Belgrade, Serbia
Zeljko Beljic
; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Predrag Rakonjac
orcid.org/0000-0003-0978-6057
; Technical Test Center, Vojvode Stepe 445A, 11000 Belgrade, Serbia
Zoran Mitrovic
orcid.org/0000-0001-7660-0844
; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Sažetak
This paper proposes a novel approach for the improvement of the long-term frequency stability measurement using an obsolete phase meter. The hypothesis of the paper states it is possible to fully automate measurement process and reduce measurement time using the standard method supported by bespoke PC software. This theory was examined in detail and experimentally validated using GPS standard method. The results of the experiment confirmed that measurement time can be reduced more than 50 %, at the expense of a measurement uncertainty increase. Still, the estimated measurement uncertainty of the proposed method is more than satisfactory for the calibration purpose of the most common oscillator types including rubidium frequency standards.
Ključne riječi
automation; frequency; long-term stability; phase angle; vector voltmeter