Skoči na glavni sadržaj

Ostalo

UPPER INCISOR PROMINENCE IS A GOOD PREDICTOR OF DIFFICULT INTUBATION

SANJA MARIČIĆ PRIJIĆ ; Klinički centar Vojvodine, Klinika za anesteziologiju i intenzivnu terapijsku skrb, Novi Sad, Srbija
ALEKSANDRA PLEĆAŠ ĐURIĆ ; Klinički centar Vojvodine, Klinika za anesteziologiju i intenzivnu terapijsku skrb, Novi Sad i Univerzitet u Novom Sadu, Medicinski fakultet, Novi Sad, Srbija
VLADIMIR DOLINAJ ; Klinički centar Vojvodine, Klinika za anesteziologiju i intenzivnu terapijsku skrb, Novi Sad i Univerzitet u Novom Sadu, Medicinski fakultet, Novi Sad, Srbija
BRANISLAVA JOROVIĆ ; Klinički centar Vojvodine, Klinika za anesteziologiju i intenzivnu terapijsku skrb, Novi Sad, Srbija
JELENA VUKOJE ; Klinički centar Vojvodine, Klinika za anesteziologiju i intenzivnu terapijsku skrb, Novi Sad, Srbija


Puni tekst: engleski pdf 117 Kb

str. 24-24

preuzimanja: 480

citiraj


Sažetak

Background and aim: One of the most important goals of pre-anesthesiologic evaluation is assessment of the airway. The aim of the present study was to determine the incidence of diffi cult intubation in surgical patients, and to establish which external anatomic factors are the best predictors of diffi cult intubation. Patients and methods: This prospective observational cross-sectional study included 200 adult patients who were scheduled to receive general anesthesia with intubation for elective surgical procedures. Results: Among 200 patients, 191 (95.5%) had normal intubation and 9 (4.5%) had difficult intubation. Age, height, body mass index, upper incisor prominence and interincisor gap were independently associated with diffi cult intubation. With every year of increase in age, the odds ratio for diffi cult intubation decreased by 7%. Odds of diffi cult intubation increased by 1.143 with each additional centimeter of patient height. Patients with prominent upper incisors were nearly seven times more likely to have diffi cult intubation. The odds of diffi cult intubation decreased by 96% in patients with the interincisor gap greater than 3 cm. Conclusion: Interincisor gap of less than 3 cm is a risk factor for difficult intubation, while those patients with prominent upper incisors are seven-fold more likely to have diffi cult intubation.

Ključne riječi

Diffi cult intubation; Prominence of upper incisors; Interincisor gap; Intubation Difficulty Scale

Hrčak ID:

209062

URI

https://hrcak.srce.hr/209062

Datum izdavanja:

18.11.2018.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.527 *