Metalurgija, Vol. 58 No. 3-4, 2019.
Prethodno priopćenje
Analysis of the incompatibility of the product with fluorescent method
A. Pacana
orcid.org/0000-0003-1121-6352
; Rzeszow University of Technology, Faculty of Mechanical Engineering and Aeronautics, Rzeszow, Poland
D. Siwiec
; Rzeszow University of Technology, Faculty of Mechanical Engineering and Aeronautics, Rzeszow, Poland
L. Bednarova
; Faculty of Business Economics of the University of Economics in Bratislava with seat in Košice, Slovakia
Sažetak
The aim is to analyze the surface of the product (posterior bearing housing) with using the fluorescent method and to demonstrate the effectiveness of the sequence application like the fluorescent method and instruments of the quality management to analyze the incompatible of the product. In the production enterprise, during the fluorescent penetration test, the incompatibility was identified on the product (posterior bearing housing), i.e. the porosity cluster. The effective of the used the sequence containing the fluorescent method, the Ishikawa diagram and the 5Why method in order to identify incompatibility, and next the source cause was demonstrated. The analyze, the sequence of the methods and the proposed improvement actions can be used in other companies to analyze quality problems.
Ključne riječi
nicel alloy; brarinc penetration fluorescent method; quality Ishikawa diagram