Skoči na glavni sadržaj

Izvorni znanstveni članak

Comparing Analysis of Loss of Coolant Accident on Bethsy Facility with Apros 6.05 and 6.06

Klemen Debelak, ; GEN energija, d.o.o Vrbina 17, 8270 Krško, Slovenija
Luka Štrubelj ; GEN energija, d.o.o Vrbina 17, 8270 Krško, Slovenija


Puni tekst: engleski pdf 1.343 Kb

preuzimanja: 168

citiraj


Sažetak

In this paper, the comparison of analysis of international standardized problem ISP 27 using
two versions of APROS process simulation software 6.05 and 6.06 is presented. Numerical
simulation of experiment Bethsy 9.1b, also known as ISP 27 was performed on a scaled down
model of a three loop, 900 MWe Framatome PWR. In the test a small LOCA, with 2-inch cold leg
break, combined with High pressure Injection System (HPIS) failure is simulated. State oriented
approach, which requires operators to start an Ultimate Procedure were used. Model was first built
in APROS 6.05 using standard modules in order to describe the volumes, heat structures and
regulation of the test facility and was then exported to APROS 6.06.
The results from both versions showed all the processes such as loop seal clearing, core
uncover and rise of cladding temperature and other processes taking place in the experiment were in
a good agreement with experimental data. However even though results were similar some
differences were noticeable. The differences in core cladding temperature, time integrated break
mass flow, core liquid level and pressurized pressure were analysed in more detail in this paper.

Ključne riječi

APROS, Loss of Coolant Accident, Bethsy, ISP 27

Hrčak ID:

247097

URI

https://hrcak.srce.hr/247097

Datum izdavanja:

28.10.2019.

Posjeta: 383 *