Design Strategy of Elastoplastic Dampers for Seismic Protection of Structures

Fengmei Pi ; 1) School of Civil and Transportation Engineering, Hebei University of Technology, 5340 Xiping Road, Beichen District, Tianjin, China 2) Institute of Architecture Civil Engineering, Langfang Normal University, 100 Aimin West Road, Langfang City, Hebei Province, China
Wenjie Ren* ; School of Civil and Transportation Engineering, Hebei University of Technology, 5340 Xiping Road, Beichen District, Tianjin, China
Bowen Chen ; School of Civil and Transportation Engineering, Hebei University of Technology, 5340 Xiping Road, Beichen District, Tianjin, China


Puni tekst: engleski pdf 2.000 Kb

str. 222-229

preuzimanja: 549

citiraj


Sažetak

A new methodology for seismic control design of MDOF structures is put forward.The methodology is developed for shear-type building frames with supplemental system of braces with dampers. Hysteretic dampers are modelled to be elasto-perfectly plastic. The mechanical parameters of the damper, the supplemental system (damper + brace) and the controlled structure are first defined. Next, based on modal analysis method, the controlled MDOF structure is converted to the equivalent SDOF structure, and the distribution of elastic stiffness of damper on the MDOF structure is derived. Then, a procedure is compiled to achieve the elastic stiffness, the yielding drift and the ductility factor of the damper on each story of the MDOF structure. Finally, the procedure is used for seismic control design of three example structures. Time history analyses show that the proposed methodology is feasible.

Ključne riječi

damper; model analysis method; seismic control design; shear-type frame