Introduction: A perivalvular extension of infection is the complication of bacterial endocarditis. Because prosthetic valve endocarditis (PVE) usually begins as periannulitis, it is not surprising that infected prosthetic valves had these complications with a higher frequency than did infected native valves. (1) In case of an aortic prosthetic valve infective endocarditis (IE), the infection has tendency to extend towards the membranous septum and into the conducting tissue. We present a case of culture-negative IE resulting in a dehiscence of a bioprosthetic aortic valve complicated by aortic root abscess and complete heart block.
Case report: 67-year-old man, who underwent aortic valve replacement (Medtronic Mosaic A25) for severe aortic valve insufficiency 15 months before, presented to the emergency department with dyspnea and syncopal episodes. Electrocardiogram demonstrated left bundle branch block with intermittent complete heart block causing ventricular pauses up to 15 seconds. An urgent pacemaker implantation was performed. During the consecutive hospital staying he developed fever accompanied by worsening of congestive heart failure. The chest radiography showed suspected pneumonia. The transesophageal echocardiography revealed perivalvular aortic root abscess with partial valve dehiscence and moderate aortic regurgitation (Figure 1,Figure 2). Inflammatory markers were elevated, while blood cultures remained sterile. The empirical antimicrobial treatment for infective endocarditis and pneumonia was initiated. Despite pharmacological measures, the patient’s condition was gradually deteriorating so he underwent early cardiac surgery. The prosthetic valve replacement together with pericardial patch reconstruction of annulus was successfully performed.
Conclusion: Culture-negative endocarditis constitutes up to 16% to 18% of PVE, (2,3) and can rarely be complicated by prosthetic aortic valve dehiscence. (4) The appearance of an AV conduction block can be a sign of underlying aortic root abscess as perivalvular complication of prosthetic aortic valve IE.