Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.18048/2021.61.05.

The Change in Low Power Steam Turbine Operating Parameters During Extractions Opening/Closing

Igor Poljak ; Department of Maritime Sciences, University of Zadar, Zadar, Croatia
Vedran Mrzljak orcid id orcid.org/0000-0003-0323-2600 ; Faculty of Engineering, University of Rijeka, Rijeka, Croatia
Ivan Gospić ; Department of Maritime Sciences, University of Zadar, Zadar, Croatia
Ivica Glavan ; Department of Maritime Sciences, University of Zadar, Zadar, Croatia


Puni tekst: engleski pdf 3.652 Kb

str. 57-78

preuzimanja: 292

citiraj


Sažetak

The paper presents steam turbine power, energy and exergy efficiencies and losses analysis during
steam extractions opening/closing. The analyzed steam turbine can be used in steam power plant
or in the marine steam propulsion system (low-power steam turbine). Steam extractions opening
and closing can have a notable influence on various turbine operating parameters, what is currently
purely exploited in the literature. Turbine developed power during steam extractions opening/closing
is direct proportional to turbine energy and exergy losses and reverse proportional to turbine exergy
efficiencies. Turbine energy efficiency is not affected by steam extractions opening/closing. Considering
all the combinations of turbine steam extractions opening/closing, it is obtained that the range of
real developed power is between 30612.91 kW and 34289.14 kW, while the range of turbine exergy
efficiencies is between 85.65% and 86.08%. The range of turbine energy power losses in all possible
observed combinations is between 5401.78 kW and 6050.30 kW, while the range of exergy destruction
is between 4949.44 kW and 5746.81 kW.

Ključne riječi

Steam turbine; steam extraction; power; losses; efficiency

Hrčak ID:

272266

URI

https://hrcak.srce.hr/272266

Datum izdavanja:

29.12.2021.

Posjeta: 628 *