Sažetak sa skupa
https://doi.org/10.26800/LV-144-supl2-CR49
External fixation with a locking plate for a tibial frac- ture complicated by osteomyelitis: a case report
Lea Kalajžić
; School of Medicine, University of Zagreb
Tin Karakaš
; School of Medicine, University of Zagreb
Maša Kopušar
; School of Medicine, University of Rijeka
Srećko Sabalić
; Department of Traumatology, “Sestre Milosrdnice” Unversity Hospital Center
Sažetak
External fixation using a locking plate is an uncommon approach, however good clinical outcomes have been reported in the literature so far. It provides certain benefits over conventional external fixators, which hinder everyday activities due to their bulkiness. Aside from being more convenient for the patient, external fixation with locking plate results in less soft tissue trauma, low-profile stable fixation and shortened hospital stay.
Ključne riječi
external fixation, locking plate fixation, osteomyelitis
Hrčak ID: