Skoči na glavni sadržaj

Ostalo

https://doi.org/10.15836/ccar2022.201

Cardiac transplantation for congenitally corrected transposition of the great arteries and dextrocardia: a case report

Mario Udovičić orcid id orcid.org/0000-0001-9912-2179 ; Dubrava University Hospital, Zagreb, Croatia
Sanda Jakšić Jurinjak orcid id orcid.org/0000-0002-7349-6137 ; University Hospital Centre Zagreb, Zagreb, Croatia
Mira Stipčević orcid id orcid.org/0000-0003-4351-1102 ; Zadar General Hospital, Zadar, Croatia
Boris Starčević orcid id orcid.org/0000-0002-3090-2772 ; ”Merkur” University Hospital, Zagreb, Croatia
Anđela Jurišić orcid id orcid.org/0000-0001-8316-4294 ; Dubrava University Hospital, Zagreb, Croatia
Igor Rudež orcid id orcid.org/0000-0002-7735-6721 ; Dubrava University Hospital, Zagreb, Croatia
Daniel Unić orcid id orcid.org/0000-0003-2740-4067 ; Dubrava University Hospital, Zagreb, Croatia
Šime Manola orcid id orcid.org/0000-0001-6444-2674 ; Dubrava University Hospital, Zagreb, Croatia


Puni tekst: engleski pdf 141 Kb

str. 201-201

preuzimanja: 73

citiraj

Preuzmi JATS datoteku


Sažetak

Ključne riječi

dextrocardia; congenitally corrected transposition of the great arteries; left ventricular assist device; heart transplantation; advanced heart failure

Hrčak ID:

287113

URI

https://hrcak.srce.hr/287113

Datum izdavanja:

8.12.2022.

Posjeta: 189 *



Introduction: Congenitally corrected transposition of the great arteries (ccTGA) is a rare anomaly comprising a minimal portion of congenital heart disease cases. Some patients are not identified until adulthood (1).

Case report: We report the case of 57-year-old female patient with congenitally corrected trans-position of large blood vessels and associated dextrocardia. Except for the previously mentioned, she had also significant dilatation and insufficiency of the systemic ventricle with severe insufficiency of the systemic atrioventricular valve. She was repeatedly hospitalized due to heart failure. In 2017 a complete pre-transplantation management was performed, and due to congestive heart failure refractory to medications and high pulmonary vascular resistance, the multidisciplinary team decided for long-term unloading with ventricular assist device as a bridge to decision. In September 2020, due to clinical deterioration, she was accepted on the urgent international list for heart transplantation, and on September 7, 2020, the patient was transferred to the operating room of cardiac surgery for heart transplantation. Postoperatively, she was treated in the cardiosurgical intensive care unit, and the course of her stay was complicated by a severe cardiac tamponade and bleeding which required surgical drainage, and by a massive ischemic cerebral insult and renal insufficiency. Also, resistant hospital strains were isolated from blood cultures and catheters for which the patient was continuously on antibiotic therapy. Finally, the patient died of septic shock 32 days after the heart transplantation.

Conclusion: Because the existing literature consists mainly of case reports, the management of a case like this one should include the stepwise introduction of the treatment modalities and close monitoring of the clinical response as well as the decision making by the heart multidisciplinary team (2).

LITERATURE

1 

Wallis GA, Debich-Spicer D, Anderson RH. Congenitally corrected transposition. Orphanet J Rare Dis. 2011 May 14;6:22. https://doi.org/10.1186/1750-1172-6-22 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/21569592

2 

Gregoric ID, Kosir R, Smart FW, Messner GN, Patel VS, La Francesca S, et al. Left ventricular assist device implantation in a patient with congenitally corrected transposition of the great arteries. Tex Heart Inst J. 2005;32(4):567–9. PubMed: http://www.ncbi.nlm.nih.gov/pubmed/16429905


This display is generated from NISO JATS XML with jats-html.xsl. The XSLT engine is libxslt.