Skoči na glavni sadržaj

Ostalo

https://doi.org/10.15836/ccar2022.261

New paradigm in graft rejection detection in heart transplantation recipients: diagnostic utility of synchrotron X-ray phase contrast imaging (GRAFT-XPCI) - a multi-centric, prospective, observational study protocol

Nikola Škreb orcid id orcid.org/0000-0003-1730-8768 ; University of Zagreb School of Medicine, Zagreb, Croatia
Filip Lončarić orcid id orcid.org/0000-0002-7865-1108 ; University Hospital Centre Zagreb, Zagreb, Croatia
Bart Bijnens orcid id orcid.org/0000-0003-3130-6937 ; Institut d’Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
Anne Bonnin orcid id orcid.org/0000-0001-5537-8682 ; Paul Scherrer Institute, Villigen, Switzerland
Hector Dejea orcid id orcid.org/0000-0003-2584-9812 ; Lund University, Department of Biomedical Engineering, Lund, Sweden
Marta Farrero Torres orcid id orcid.org/0000-0002-2404-8821 ; Hospital Clinic Barcelona, Hospital Clinic Cardiovascular Institute (ICCV), Barcelona, Spain
Patricia Garcia Canadilla orcid id orcid.org/0000-0002-0223-1617 ; Hospital Sant Joan de Déu Barcelona, Barcelona, Spain
Sven Lončarić orcid id orcid.org/0000-0002-4857-5351 ; University of Zagreb, Faculty of Electrical Engineering and Computing, Zagreb, Croatia
Angela López-Sainz orcid id orcid.org/0000-0001-7433-2137 ; Hospital Clinic Barcelona, Hospital Clinic Cardiovascular Institute (ICCV), Barcelona, Spain
Hrvoje Gašparović orcid id orcid.org/0000-0002-2492-3702 ; University of Zagreb School of Medicine, Zagreb, Croatia
Ivana Ilić orcid id orcid.org/0000-0003-1988-6684 ; University of Zagreb School of Medicine, Zagreb, Croatia
Davor Miličić orcid id orcid.org/0000-0001-9101-1570 ; University of Zagreb School of Medicine, Zagreb, Croatia
Igor Rudež orcid id orcid.org/0000-0002-7735-6721 ; University of Zagreb School of Medicine, Zagreb, Croatia
Boško Skorić orcid id orcid.org/0000-0001-5979-2346 ; University of Zagreb School of Medicine, Zagreb, Croatia
Ivo Planinc orcid id orcid.org/0000-0003-0561-6704 ; University of Zagreb School of Medicine, Zagreb, Croatia
Maja Čikeš orcid id orcid.org/0000-0002-4772-5549 ; University of Zagreb School of Medicine, Zagreb, Croatia


Puni tekst: engleski pdf 802 Kb

str. 261-262

preuzimanja: 90

citiraj

Preuzmi JATS datoteku


Sažetak

Ključne riječi

heart transplantation; graft rejection; synchrotron imaging; histology

Hrčak ID:

287734

URI

https://hrcak.srce.hr/287734

Datum izdavanja:

8.12.2022.

Posjeta: 213 *



Background: Graft rejection remains the most important complication after heart transplantation (HTx). Endomyocardial biopsy (EMB) is the gold standard in HTx follow-up, however, conventional histopathological (HP) analysis is limited by tissue damage during preparation, 2-dimensional (2D) analysis, and low inter-observer agreement in rejection grading. X-ray phase contrast imaging (X-PCI) has shown potential for non-destructive imaging of the myocardium, enabling high-resolution 3-dimensional (3D) analysis with fibrosis and fibre orientation quantification. (1)

Methods and Design: GRAFT-XPCI is a multi-centric, prospective observational study aiming to prove non-inferiority of X-PCI in graft rejection diagnosis, vs. conventional HP (Figure 1). It will include approximately 400 patients in standard post-HTx follow-up at 3 clinical centres: University Hospital Centre Zagreb, Dubrava University Hospital and Hospital Clinic Barcelona. Collected data will include EMB samples, patient history, laboratory, electrocardiogram (ECG), coronarography and echocardiographic data. EMB specimens will be initially imaged by X-PCI at the Paul Scherrer Institute (Villigen, Switzerland), producing digital 3D imaging datasets (at 0.65 um pixel resolution) for computational analysis, and then prepared for HP microscopy at the University of Zagreb School of Medicine. Three datasets will be generated for analysis - 2D X-PCI dataset, 3D X-PCI dataset, and 2D HP images. Acquired X-PCI images and HP slides will be diagnostically graded (ISHLT 2004. grading system) (2), comparatively assessed by at least two observers in a blinded fashion, further analysed in conjunction with gathered clinical data. Computer methods for the automatic and semi-automatic analysis of digital image datasets will be developed as an additional output.

FIGURE 1 GRAFT- X-ray phase contrast imaging study.
CC202217_9-10_261-2-f1

Conclusion: GRAFT-XPCI will: 1) compare X-PCI and conventional HP in graft rejection analysis, 2) enable insight into structural and pathophysiological processes in graft rejection after HTx, 3) extend the amount of information gained by EMB analysis. The development of new research tools and imaging protocols should widen future research of EMB analysis in various cardiac conditions. This study has been fully supported by the Croatian Science Foundation under the trial registration no. UIP-2020-02-5572.

LITERATURE

1 

Planinc I, Garcia-Canadilla P, Dejea H, Ilic I, Guasch E, Zamora M, et al. Comprehensive assessment of myocardial remodeling in ischemic heart disease by synchrotron propagation based X-ray phase contrast imaging. Sci Rep. 2021 July 7;11(1):14020. https://doi.org/10.1038/s41598-021-93054-6 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/34234175

2 

Stewart S, Winters GL, Fishbein MC, Tazelaar HD, Kobashigawa J, Abrams J, et al. Revision of the 1990 working formulation for the standardization of nomenclature in the diagnosis of heart rejection. J Heart Lung Transplant. 2005 November;24(11):1710–20. https://doi.org/10.1016/j.healun.2005.03.019 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/16297770