Skoči na glavni sadržaj

Izvorni znanstveni članak

Improvement of the process of feeding the slag-foaming material to the electric arc furnace (EAF), using of the sound

J. Schwietz ; Szar S.A, Częstochowa, Poland
B. Panic ; Silesian University of Technology, Faculty of Material Science, Katowice, Poland


Puni tekst: engleski pdf 147 Kb

str. 201-203

preuzimanja: 243

citiraj


Sažetak

The research described, aimed to determine the value of the sound level (originating exclusively from the operating electric arc) at which the feeding of the slag foaming material to the Electric Arc Furnace (EAF) should start, in correlation with the stabilization of the furnace’s active power consumption level. For this purpose, the frequency band generated by the working electric arc was extracted from the entire spectrum of sound emitted by the furnace. Using sound analysis in 1/3 octave bands, the focus was on the band with a center frequency of 100 Hz. It was found that feeding the foaming material should start at a sound level of 103 dB.

Ključne riječi

steel, EAF, active power, noise emission, Poland

Hrčak ID:

290052

URI

https://hrcak.srce.hr/290052

Datum izdavanja:

3.4.2023.

Posjeta: 719 *