Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.5599/jese.1959

Zinc (II) removal from simulated wastewater by electro-membrane extraction approach: Adopting an electrolysis cell with a flat sheet supported liquid membrane

Noor R. Kadhim orcid id orcid.org/0000-0003-4765-9921 ; Environmental Engineering Department, College of Engineering, University of Baghdad
Hussain M. Flayeh ; Environmental Engineering Department, College of Engineering, University of Baghdad
Ali H. Abbar ; Biochemical Engineering Department ,Al-Khwarizmi College of Engineering , University of Baghdad


Puni tekst: engleski pdf 1.020 Kb

str. 1097-1112

preuzimanja: 44

citiraj


Sažetak

The aim of this study is to utilize the electromembrane extraction (EME) system as a manner for effective removal of zinc from aqueous solutions. A novel and distinctive electrochemical cell design was adopted consisting of two glass chambers, a supported liquid membrane (SLM) housing a polypropylene flat membrane infused with 1-octanol and a carrier. Two electrodes were used, a graphite as anode and a stainless steel as cathode. A comprehensive examination of several influential factors including the choice of carrier, the applied voltage magnitude, the initial pH of the donor solution, and the initial concentration of zinc was performed, all in a concerted effort to ascertain their respective impacts on the efficiency of zinc elimination. Two distinct carriers, namely tris(2-ethylhexyl) phosphate (TEHP) and bis(2-ethylhexyl) phosphate (DEHP) were evaluated, in a tandem with utilization of 1-octanol. The results revealed essential role played by the applied voltage in augmenting the rate of mass transfer of zinc across the membrane. The best operating conditions were utilized for 1-octanol enriched with 1.0 vol.% bis(2-ethylhexyl) phosphate as a carrier, applied voltage of 60 V, initial pH of 5, initial zinc concentration of 15 mg L-1, extraction duration of 6 hours, and stirring rate of 1000 rpm. Surprisingly, operating under these meticulously devised conditions culminated in the outstanding removal efficiency of 87.3 %. In comparison with no applied voltage, a substantial enhancement in removal efficiency was observed, trans­cending from a meager 36.67 % to an impressive 87.3 % at 60 V, suggesting thus a tremen­dous potential of EME as an efficacious technique for the elimination of heavy metals.

Ključne riječi

Heavy metal removal; ion transport; electrochemical treatment; membrane selectivity; organic solvent; membrane carriers

Hrčak ID:

311034

URI

https://hrcak.srce.hr/311034

Datum izdavanja:

7.12.2023.

Posjeta: 117 *