Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.15644/asc58/1/2

Comparison of Three Different Orthodontic Adhesives Bonded to Metallic and Ceramic Brackets: SEM and SEM/EDX Analysis (In VitroStudy)

Arif Arifi ; Stomatološki fakultet Sveučilišta u Tetovu, Republika Sjeverna Makedonija
Elizabeta S. Gjorgievska ; Odjel za dječju i preventivnu stomatologiju Stomatološkog fakulteta Sveučilišta Sv. Kiril i Metod, Skoplje, Republika Sjeverna Makedonija
Irena Gavrilovi ; Odjel za ortodonciju Stomatološkog fakulteta Sveučilišta Sv. Kiril i Metod, Skoplje, Republika Sjeverna Makedonija
Nichola J. Coleman ; Škola znanosti Fakulteta inženjerstva iznanosti Sveučilišta u Greenwichu, Chatham Maritime, Kent ME4 4TB, Velika Britanija
Marko Vuletić orcid id orcid.org/0000-0002-0020-5247 ; Sveučilište u Zagrebu, Stomatološki fakultet, Zavod za oralnu kirurgiju i Sveučilišna bolnica Zagreb, 10 000 Zagreb, Hrvatska
Dragana Gabrić ; Sveučilište u Zagrebu, Stomatološki fakultet, Zavod za oralnu kirurgiju i Sveučilišna bolnica Zagreb, 10 000 Zagreb, Hrvatska


Puni tekst: engleski pdf 2.845 Kb

str. 18-29

preuzimanja: 482

citiraj

Puni tekst: hrvatski pdf 2.845 Kb

str. 18-29

preuzimanja: 97

citiraj


Sažetak

Objectives: To compare three different orthodontic adhesives (Transbond XT Light Cure Adhesive, Heliosit Orthodontic, Fuji Ortho LC) bonded to two types of orthodontic brackets: ceramic brackets (Fascination Roth 0.22) and metallic brackets (Topic Roth 0.22, Dentaurum). Materials and methods: The study was performed on 18 human teeth (6 for each adhesive). The prepared teeth were divided into three groups according to the examination time. Subsequently, they were observed after 1, 2 and 3 weeks following bonding. After the experimental procedure, the teeth samples were cut in half along the longitudinal axis in the vestibulo-oral direction, fixed with conductive carbon cement, placed in a high-vacuum evaporator and then coated with carbon. One half of each sample was observed under a Field-emission gun scanning electron microscope (FEG-SEM Hitachi SU 8030, Japan), while on the second half of the samples qualitative (X-ray line-scans) and semi-quantitative point X-ray energy dispersive analyses (EDX) were performed with Thermo Noran (USA) NSS System 7, equipped with Ultra Dry detector (30 mm2 window). Results: Transbond XT had an ideal bond with the enamel and the bracket base, with rare presence of microgaps and cracks in the enamel. Heliosit Orthodontic demonstrated a better bond relationship with the bracket base than the enamel, where-as in the latter the presence of microgaps in the bond was observed. The microphotographs of Fuji Ortho LC demonstrated many cracks inside the adhesive, and some of them continued to move forward into the enamel surface. Therefore, an impression of a very solid bond relationship with the enamel exists, with cracks being present in the enamel surface and never at the enamel-adhesive interface. Microgaps also appeared at the bracket-adhesive interface. Conclusion: Transbond XT is a highly filled composite resin and is an ideal orthodontic adhesive in each aspect examined, with an ideal enamel-adhesive and bracket-adhesive interface. Heliosit Orthodontic provides better bracket-adhesive interface compared to the enamel. Fuji Ortho LC as a solid resin-modified GIC provides a better enamel-adhesive interface, compared to the bracket base.

Ključne riječi

Orthodontic Brackets; Dental Bonding; Dental Cements; Composite Resins; Adhesives; Bracket; Resin modified glass ionomer cement; SEM; EDX

Hrčak ID:

315328

URI

https://hrcak.srce.hr/315328

Datum izdavanja:

25.3.2024.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.132 *